Work Italia is certified ISO 9001:2015 as manufacturer for Protective Equipment for safety against electrical risks and IPD (Individual Protection Devices).
Our product are tested and certified by accredited laboratories I.N.R.I.M. National Institute of Metrological Research, ABB SACE, SIEMENS SVEPPI, ENEL, NEMKO, CESI, IMQ, TÜV, SGS, PPC Greece, CREDEG Algeria and by other Official Laboratories in conformity with the International Standards (IEC), the European Standards (EN/CE Mark), the ENEL, TERNA, RFI, TRENITALIA Specifications and the Standards and Technical Specifications of other European countries.
Work Italia has a long list of Certified Products:
Item |
Product Description |
Certification |
EF30 |
Rod for fuse extraction |
ENEL Specification EA 0375 |
GI02,5/10 |
Dielectric gloves 2500V Class 00, size 10-HC40151990 |
IEC 60903 |
GI05/10 |
Dielectric gloves 5000V Class 0 Size 10-HC40151990 |
IEC 60903 |
GI10/10 |
Dielectric gloves 10000 V, Class 1, size 10- HC40151990 |
IEC 60903 |
GI20/10 |
Dielectric gloves 20000V Class 2 Size 10-HC40151990 |
IEC 60903 |
GI30/10 |
Dielectric gloves 30000 V, Class 3, size 10-HC40151990 |
IEC 60903 |
GI40/10 |
Dielectric gloves 40000 V, Class 4, size 10 |
IEC 60903 |
ISOLPLAST 353 |
Insulating cover for temporary protection against accidental contact at energized LV installations up to 1000 V |
IEC 61112 |
MPC 93/1/2/3/4 |
Short circuit insulating piercing connectors for LV insulated conductors |
ENEL Specification EA 0138 |
MT/BM-50 |
Short circuiting & grounding equipment for electric cabins and MV installations |
IEC 61230 |
MT/BM-95 |
Short circuiting & grounding device for electric cabins section 95mm2 |
IEC 61230 |
MT/PF-50 |
Short circuiting & grounding equipment with clamps for ball fixed points |
IEC 61230 |
MT/PF-95 |
Short circuiting & grounding device with clamps for ball fixed points |
IEC 61230 |
PV Insulating Rod |
High insulating tube-rods made of synthetic resin reinforced by fiberglass |
IEC 61235 |
PE Insulating Rod |
High insulating tube-rods made of epoxy resin reinforced by fiberglass |
IEC 61235 |
PVR Insulating Rod |
High insulating tube-rods made of synthetic resin reinforced by fiberglass filled by closed cells foam polyurethane |
IEC 60855 |
RBT750-E |
Voltage detector |
ENEL Specification EA 0118 |
RMT1030/U |
Electronic capacitive detector of voltage presence/absence - HC 90303930 |
IEC 61243-1 |
RMT3090/U |
Voltage detector for use on HV with universal attack type U |
IEC 61243-1 |
WBT127 |
Short circuiting and grounding equipment for LV insulated conductors |
ENEL Specification EA 0127 |
WI198CE |
Continuity and equipotential equipment for use during jointing od spiral cables |
ENEL Specification EA 0320/19 |
WI3/100 |
Insulating rubber carpet, nom. thickness 3mm - width 100 cm |
IEC 61111 Class 3 |
WI332/E-25 |
Short circuiting and grounding equipment for MV overhead bare conductor 3-32mm |
IEC 61230 |
WI4,5/100 |
Insulating rubber carpet, nom.thickness 4,5 mm.-width:100 cm. |
IEC 61111 Class 4 |
WI560/A-50-70-95-120 |
Short circuiting and grounding equipment for HV overhead lines |
IEC 61230 |
WI560/C-50-70-95-120 |
Short circuiting and grounding equipment for HV substations |
IEC 61230 |
WI6/100 |
Insulating rubber carpet, nom.thickness:6mm.-width:100 cm. |
IEC 61111 Class 4 |
WIDTSE250 |
Short circuiting and grounding equipment for disconnectable square and straight unipolar connectors with contact plug 250 A on MV overhead bundle conductors |
ENEL Specification EA 0287 |
WIDTSE400 |
Short circuiting and grounding equipment for disconnectable terminals and derivations connectors with contact plug 400 A on MV overhead bundle conductors |
ENEL Specification EA 0290 |
WIDGSE250 |
Short circuiting and grounding equipment for disconnectable external cone connectors with contact plug 250 A on MV overhead bundle conductors |
ENEL Specification EA 0274 |
WIRTRD/EA0271 |
Voltage detector with phase correlation for MV lines and substations |
ENEL Specification EA 0271 |